1.SC Codes
365
Error Name/Error Condition/Major Cause/Solution
Replace the Transport Motor Cooling Fan on the LCT1.
Replace the harness
Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
The cooling fan alarm detected an error when the A3 LCT cooling fan was turned
ON.
A3 LCT cooling fan defective/disconnected
Harness for A3 LCT cooling fan defective
PCB defective
1. Check the connectivity of the harness of the cooling fan, and replace it.
2. Replace the cooling fan.
3. Replace the PCB.
Error Name/Error Condition/Major Cause/Solution
LCT1: Connection configuration error (LCT not connected)
LCT2 or LCT3 is detected while LCT1 is not installed.
The interface harness on the LCT1 broken
PCB on the LCT1 defective
Replace the interface harness on the LCT1
Replace the PCB on the LCT1
Error Name/Error Condition/Major Cause/Solution
LCT1: Connection configuration error (Bridge unit connection error)
Without LCT2, the bridge unit is connected to LCT1.
The bridge unit is connected to LCT1 in single LCT configuration.
The interface harness on the LCT2 disconnected
Power cord of the LCT2 disconnected
PSU on the LCT2 defective
Remove the bridge unit from the LCT1.
Reconnect the interface harness connector on the LCT2.
Plug the power cord of the LCT2.
Replace the PSU on the LCT2.
Error Name/Error Condition/Major Cause/Solution
Multi bypass tray cooling fan error