1.SC Codes
378
Error Name/Error Condition/Major Cause/Solution
Cycle the main power switch OFF/ON.
Error Name/Error Condition/Major Cause/Solution
Ethernet TCP/IP: Invalid configuration during enable
When IPDS connection is used
Configuration error related to communication with the host system (IPDS)
1. Reboot the DFE.
2. Replace the mother board of the DFE. (Because the NIC is an on-board
NIC)
Error Name/Error Condition/Major Cause/Solution
Internal printing: File system error
File system error of an internal print (an internally-generated print job)
2. Reinstall the DFE System.
Error Name/Error Condition/Major Cause/Solution
Unexpected network condition
Unexpected error due to the network environment
The network board or mother board may be defective, or the setting file or device
driver may be corrupted.
1. Reboot the DFE.
2. Reinstall the DFE System.
3. Replace the mother board on the DFE. (Because the NIC is an on-board
NIC)
Error Name/Error Condition/Major Cause/Solution