1.SC Codes
378
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
Cycle the main power switch OFF/ON.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-
06
B
Ethernet TCP/IP: Invalid configuration during enable
When IPDS connection is used
Configuration error related to communication with the host system (IPDS)
1. Reboot the DFE.
2. Replace the mother board of the DFE. (Because the NIC is an on-board
NIC)
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-10
B
Internal printing: File system error
-
File system error of an internal print (an internally-generated print job)
1. Reboot the DFE.
2. Reinstall the DFE System.
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-
11
B
Unexpected network condition
-
Unexpected error due to the network environment
The network board or mother board may be defective, or the setting file or device
driver may be corrupted.
1. Reboot the DFE.
2. Reinstall the DFE System.
3. Replace the mother board on the DFE. (Because the NIC is an on-board
NIC)
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
SC911-20
B
Program check - Type 1
SC911-21
B
Program check - Type 2
SC911-22
B
Program check - Type 3
-
Program error
1. Reboot the DFE.