1.SC Codes
385
SC NO.
Level
Error Name/Error Condition/Major Cause/Solution
00
An error occurred because the number of records exceeded the limit for images
managed in the service layer of the firmware.
This can occur if there are too many application screens open on the operation
panel.
Logging only.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC997-
00
D
Application function selection error
The application selected by the operation panel key operated abnormally (No
response, abnormal ending).
Software bug (mainly the application)
Check the optional RAM, DIMM, boards required by the application program.
Check if the combination of downloaded programs are correct.
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC998-
00
D
Application start error
No application was registered to system within a specified time after the main
power was turned on.
(No application starts/All applications have been terminated abnormally)
Application started but cannot be drawn now for some reason.
Software bug (mainly the application)
The optional RAM, DIMM, boards required by the application program. Are
not installed correctly.
Turn the main power off/on.
Check the optional RAM, DIMM, boards
Check the combination of programs
Replace the controller board.

Table of Contents