1.SC Codes
36
Error Name/Error Condition/Major Cause/Solution
machine off/on to return from SC status.
Reset or replace the toner bottle.
Replace the toner bottle motor.
Error Name/Error Condition/Major Cause/Solution
When the TD sensor control voltage (Vtcnt) is 4.3V, the TD sensor output (Vt) is
less than 0.7V.
Details:
When executing TD sensor initialization (SP3-030), the machine checks the
development unit for the presence of developer. If the error condition is detected at
this point, the machine determines that there is no developer and issues the SC.
There is an extremely low amount of developer.
Error Name/Error Condition/Major Cause/Solution
Toner supply error (K) : Sub-hopper 1 (front)
Toner supply error (C) : Sub-hopper 1 (front)
Toner supply error (M) : Sub-hopper 1 (front)
Toner supply error (Y) : Sub-hopper 1 (front)
Toner supply error (S) : Sub-hopper 1 (front)
Error occurs if ID Pattern adhesion (SP3-300-***) < Lower limit threshold (SP3-
301-***), and Toner Supply Clutch cumulative time (SP3-301-***) > Feed counter