Parameters:
<CrestFactor> float
Range: 0 to 80
Increment: 0.01
*RST: 0
Example: see Chapter 13.1.2, "Generating an I/Q modulated signal",
on page 215
Manual operation: See "Crest Factor" on page 134
[:SOURce]:IQ:WBSTate
<State>
Selects optimized settings for wideband modulation signals.
Parameters:
<State> 1 | ON | 0 | OFF
*RST: 0
Example: See Chapter 13.1.2, "Generating an I/Q modulated signal",
on page 215.
Manual operation: See "I/Q Wideband" on page 133
13.16 SOURce:PHASe subsystem
[:SOURce]:PHASe......................................................................................................... 272
[:SOURce]:PHASe:REFerence........................................................................................272
[:SOURce]:PHASe <Phase>
Specifies the phase variation relative to the current phase.
Parameters:
<Phase> float
Range: -360 to 360
Increment: 0.1
*RST: 0
Default unit: DEG
Example: See Chapter 13.1.2, "Generating an I/Q modulated signal",
on page 215.
Manual operation: See "Delta Phase" on page 93
[:SOURce]:PHASe:REFerence
Adopts the phase set with command [:SOURce]:PHASe as the current phase.
Example:
See Chapter 13.1.2, "Generating an I/Q modulated signal",
on page 215.
SOURce:PHASe subsystem