This section describes special commands that allow a fast frequency and level setting.
:FFASt.......................................................................................................................... 243
:PFASt.......................................................................................................................... 243
:FFASt <Freq>
Special command to set the RF output frequency with minimum latency. No unit (e.g.
Hz) allowed.
Bypasses the status system so command *OPC? cannot be appended.
Parameters:
<Freq> float
Example:
FFASt 12750000000
:PFASt
<Pow>
Special command to set the RF output level with minimum latency at the RF output
connector. This value does not consider a specified offset. No unit (e.g. dBm) allowed.
Bypasses the status system so command *OPC? cannot be appended.
Parameters:
<Pow> float
Example:
:PFASt -20
13.11 OUTPut subsystem
:OUTPut:AFIXed:RANGe:LOWer?...................................................................................243
:OUTPut:AFIXed:RANGe:UPPer?....................................................................................244
:OUTPut:AMODe........................................................................................................... 244
:OUTPut[:STATe]:PON....................................................................................................244
:OUTPut[:STATe]............................................................................................................245
:OUTPut:AFIXed:RANGe:LOWer?
Queries the minimum level which can be set without the attenuator being adjusted
(Attenuator FIXed).
Return values:
<Lower> float
Default unit: dBm
Example: See Chapter 13.1.2, "Generating an I/Q modulated signal",
on page 215.
Usage: Query only