1 = Pulse period
2 = Pulse width
3 = Double pulse width
4 = Double pulse delay
9.6.1 Pulse modulation settings
Access:
► Select "SGMA-GUI > Instrument Name > Pulse Modulation".
The "Pulse Modulation" dialog contains all parameters required to configure pulse
modulation and pulse signal generation.
State
Activates pulse modulation.
The R&S SGMA-GUI indicates an activated pulse modulation as follows:
Remote command:
[:SOURce<hw>]:PULM:STATe on page 280
Source
Selects between the internal "Pulse Generator", or an "External" pulse signal for the
modulation. In the later case, the instrument expects the pulse modulation signals at
the "TRIG" connector.
Remote command:
[:SOURce<hw>]:PULM:SOURce on page 280
Polarity
Sets the polarity of the active slope of the modulation signal for "Source > External".
Remote command:
[:SOURce<hw>]:PULM:POLarity on page 280
External Impedance
Selects the input impedance for an external pulse modulation signal.
Pulse modulation