Sirius 800 Series User Manual 5905 Sirius 800 Series Video Crosspoint Module Crosspoint Modules 10.1
Iss 5 Rev 7 Page 160 © 2017 SAM
Yellow
Switch Flashes on a take signal
when switching a route
Off - normal state
Flashes - each time a route is set
Blue/Green
Fugue
Status
CPU status
The LED is approximately
25 mm (1 Inch) from the
edge of the board.
Flashing Green, Green, Blue -
normal operation, the CPU is
programmed and running
Brief Flash Red at startup - normal
Flashing Red - CPU error. Remove
module and refit to force a reboot.
Red
Xpt Alarm Displays if there is a
problem with any
crosspoints
Off - normal state
On solid - problem with one or more
crosspoints on the module.
Flashing - Crosspoint module
overheating, make sure the fan
assemblies are all closed and the fans
are all operating correctly.
Yellow
Active Route is active on
crosspoint
Flashing - when this module is routing
one or more signals to live outputs.
Removing the crosspoint module will
disturb the signal(s) passing through
the crosspoint module.
Red
Route Fail Illuminated if a route failure
has been detected on this
crosspoint
Off - normal state
Flashing - receiving error messages
related to a route failure
LED Color Label Detail Status
Table 34 5905 Video Crosspoint Module LED Information (Continued)