14 - 56
ELECTRICAL SYSTEM
!
If the spark plug wire (pointAin the left picture)
is installed incorrectly, it will cause the engine to shut
down.
A
Performance parameters
Item
Value
Unit
Min Rated Max
Calibration voltage / 14 / V
Operating voltage 6 14 16.5 V
Resistance
20--25
P r i m a r y
winding
466 530 593
Secondary
winding
8.27 9.4 10.53
Primary current
(Charging time 3.9ms)
7.4 8.0 8.6 A
Secondary voltage
(Load 35pF)
34 / / kV
Ignition energy
(Zener voltage 1000V)
40 / / mJ
Fault diagnosis
The ECU does not perform the fault diagnosis function for
the ignition coil, so there is no ignition coil related code
in the fault code list. If there is no ignition, please check
whether the ignition coil connector is well connected,
whether the pins are deformed, and whether the ignition
coil wire and the spark plug are in good contact.