T
he menu provides access to the following areas:
Device info
Diagnostics
Device restart
Settings
Procedure
Pr
ess the OK pushbutton 4 twice in succession to call up the menu.
Use the arrow buttons 1, 2 to change to the desired menu item.
Confirm the desired menu item using the OK pushbutton 4.
Use the same pushbuttons to navigate through the submenus.
Press the Back pushbutton 3 to return to the higher-level menu item.
Press the Back pushbutton 3 multiple times to return to the status display.
Do not press any pushbutton for some time so that the display returns to the
status display.
Device info
Y
ou will find information about the following subjects in the area:
Hardware:For example type code, part numbers, serial numbers, firmware versions,
functional scope of device
Configuration: For example device name, application name, checksum, date of last
configuration, functional scope of configuration
Service interfaces: Information on whether access to individual interfaces and serv‐
ices is activated or deactivated
Fieldbus: For example MAC address, IP address, subnet
network: e.g., MAC address, IP address, subnet (Ethernet for data output, configura‐
tion and diagnostics)
Data output: For example status, destination IP address
The Functionality of the device and Functionality of the configuration show whether a configu‐
ration is compatible with the firmware version of a device. This can be important when
exchanging a device, for example.
Configuration and firmware version of a device are compatible if the following condi‐
tions are met:
The 1st place of both numbers must be identical
The 2nd place for the device must be at least as large as that for the configuration
The 3rd place does not have an effect on the compatibility
Diagnostics
Chec
k whether the safety laser scanner is being dazzled by an external light source in
the scan plane, e.g., sun, halogen light, infrared light source.
Intrusions: Position and time of the last 10 objects in a protective field that have led
to a safety output switching to the OFF state.
Messages: Error code and error type of the last 10 error messages.
Service: Currently measured contamination of the optics cover, operating hours,
number of power-up processes.
Device restart
Y
ou have the following options in the Device restart area:
Restart the safety laser scanner.
TROUBLESHOOTING 11
8025220/1L9Q/2023-08-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA
149
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg