Setup
3.4 Inputs and outputs
FST020 Function manual
86 Function Manual, 09/2017, A5E42949526-AA
Setting
0.0 l to 99999997952 l
Default
1.00 I
Related
Path
Setup Inputs and outputs Channel 4 - input/output Pulse output Amount per pulse
3.4.3.4.7 Pulses per amount
Description
Number of pulses which will be output when configured amount is reached.
Setting
1 to 65535
Default
1
Related
Path
Setup Inputs and outputs Channel 4 - input/output Pulse output Pulses per
amount
3.4.3.4.8 Pulse width units
Description
Units of pulse duration value used to configure Ch4 pulse width.
Setting
s (seconds); ms (milliseconds); μs (micro seconds)
Default
s (seconds)
Related
Path
Setup Inputs & outputs Channel 4 - input/output Pulse output Pulse width units
3.4.3.4.9 Polarity
Description
Logical polarity of pulse output.
Setting
Active high level; Active low level
Default
Active high level
Related
Path
Setup Inputs and outputs Channel 4 - input/output Pulse output Polarity