SIMATIC - ET 200pro motor starter
10-32 GWA 4NEB 950 5661-02 DS 04
10.10.2 Device parameters – settings
The following table shows the settings of the device parameters:
10.10.3 Signal
The mechanical braking delivers the following signal when the brake output is
switched on:
Device parameters Default Adjustment range
Brake release delay on starting 0 -2.5 s to 2.5 s
Increment: 0.01 s
Brake hold time on stopping 0 0 s to 25 s
Increment: 0.01 s
Table 10-18: Device parameters for mechanical braking – settings
Signal
Mechanical braking active
Table 10-19: Mechanical braking – signal