SIMATIC – ET 200pro motor starter
GWA 4NEB 950 5661-02 DS 04
3-9
3.7 Connecting the cables
Caution
The plug insert at connection X1 of the maintenance switch is fitted at 180° in
relation to the plug insert at connection X1 of a motor starter. This prevents an
X1 connection cable for the maintenance switch from being connected to a
motor starter.
Drawing Procedure/Description
1
2
Connect the cables and power
jumpers according to your config-
uration on the corresponding con-
nections.
Then lock the connected cables
and power jumpers.
3
4
Connect the M12 cables accord-
ing to your configuration on the
corresponding connections.
Tighten the securing ring by hand
as tightly as possible.
Table 3-5:Connecting the cables