EasyManua.ls Logo

Siemens SIMATIC ET 200pro - Integration into the User Program

Siemens SIMATIC ET 200pro
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIMATIC - ET 200pro motor starter
2-8 GWA 4NEB 950 5661-02 DS 04
Setting the parameters for DP slave
8. To obtain diagnoses of the assemblies, please set the following parameters
of the individual assemblies:
- In the dialog field 'Properties DP slave for ET 200pro'
Startup with target <> actual configuration: Enable
Assembly change during operation: Enable
- In the dialog field "Properties DP slave for DSe,
Assembly / DP identifier 4 (in the configuration table)
Diagnosis: Enable group diagnosis
- For the motor starter, set the base parameter for the rated operating cur-
rent
9. Save the configuration.
Setting the parameters for motor starters
10. Set at least in the base parameters the rated operating current of the motor
to be operated at the motor starter. Setting other parameters is optional.
2.7 Integration into the user program
1. In the KOP / AWL / FUP editor in the OB1, create the user program.
2. Save the project in the SIMATIC Manager.
3. Load the configuration into the DP master.
AWL
U E 0.0 And input 0.0 (switch ON)
S A 0.0 Set output 0.0
UN E 0.1 And not input 0.1 (switch OFF)
R A 0.0 Reset output 0.0

Table of Contents