Data formats and data records
SIMATIC – ET 200pro motor starter
GWA 4NEB 950 5661-02 DS 04
D-39
Identification data
Data record 231 – I&M 0 (Identification & Maintenance Function) – provides the
following data from all ET 200pro high feature assemblies.
Byte no. Coding
(hex)
Meaning Note
I&M header
0 ... 1 F1 11 SZL-ID SZL = system state list
2 ... 3 00 01 Index (00 42 or 00 01) I&M 0
4 ... 5 00 36 Block length (in bytes) For following blocks (56 bytes)
6 ... 7 00 01 Number of blocks For following blocks (1)
I&M0 – data block 0
8 ... 9 00 01 Index (00 42 or 00 01) I&M 0
10 ... 11 00 2A MANUFACTURER_ID 42 = manufacturer designation SIEMENS
12 ... 31 (20 bytes) ORDER_ID Order number
32 ... 47 (16 bytes) SERIAL_NUMBER Serial number
48...49 (2 bytes) HARDWARE-REVISION Hardware version status or product status
50 ... 53 (4 bytes) SOFTWARE-REVISION Firmware status
54...55 (2 bytes) REV_COUNTER Provides information on parameterized
changes on the module. After each change,
the "REV_COUNTER" is increased.
56 ... 57 (2 bytes) PROFILE_ID Provides information on the PROFIBUS pro-
file supported by the device and the
Device family to which the device belongs.
58 ... 59 (2 bytes) PROFILE_SPECIFIC_TYPE Serves as a supplement to the object
"PROFILE_ID" and contains
An advanced profile specification.
60 ... 61 (2 bytes) IM_VERSION Provides information on the version of the
identification data (01 01
hex
= Version 1.1).
62 ... 63 (2 bytes) IM_SUPPORTED Provides information on the present identifi-
cation data (index 2 to 4).
Table D-22: Data record 231 - I&M 0 'Identification data'