EasyManuals Logo

Siemens Simodrive 611 Planning Guide

Siemens Simodrive 611
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
5
05.01
5.3 Resolver control with standard and analog interface 6SN11180B_110AA0
5-110
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) 05.01 Edition
5.3 Resolver control with standard and analog interface
6SN11180B_110AA0
For 1FK6 and 1FT6 motors with resolvers, a control module is available which
includes incremental shaft encoder interface with TTL signal output for external
processing. This is available as 1axis and 2axis versions. All of the axis
specific settings are made on the control board.
1axis version
2axis version
X321X322
96 96
22
9
16
15
75
20
24
14
56
22
9
16
15
75
20
24
14
56
AS2
AS1
663
9
65.2
9
65.1
9
X321
96
22
9
16
15
75
20
24
14
56
AS2
AS1
663
9
X392X312
X391X311
X391X311
9
258
15
65.1
9
0.8 Nm 0.8 Nm
M3 / 0.8 Nm M3 / 0.8 Nm
Version label
X331
X332
X332
X331
M3 / 0.8 NmM3 / 0.8 Nm
KP
T
Drift
TN
kp
T
Drift
TN
KP
T
Drift
TN
Fig. 5-4 Resolver control with standard interface and analog interface
Note
When using nonPELV circuits at terminals AS1, AS2, connector coding must
be used so that the connectors cannot be interchanged (refer to EN602041,
Section 6.4).
Order No. of the coding, refer to Catalog NC 60.
Resolver control
with standard
interface
5 Control Modules

Table of Contents

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals