5
05.01
5.3 Resolver control with standard and analog interface 6SN1118–0B_11–0AA0
5-110
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
5.3 Resolver control with standard and analog interface
6SN1118–0B_11–0AA0
For 1FK6 and 1FT6 motors with resolvers, a control module is available which
includes incremental shaft encoder interface with TTL signal output for external
processing. This is available as 1–axis and 2–axis versions. All of the axis–
specific settings are made on the control board.
1–axis version
2–axis version
–X321–X322
96 96
22
9
16
15
75
20
24
14
56
22
9
16
15
75
20
24
14
56
AS2
AS1
663
9
65.2
9
65.1
9
–X321–
96
22
9
16
15
75
20
24
14
56
AS2
AS1
663
9
–X392–X312
–X391–X311
–X391–X311
9
258
15
65.1
9
0.8 Nm 0.8 Nm
M3 / 0.8 Nm M3 / 0.8 Nm
Version label
–X331
–X332
–X332
–X331
M3 / 0.8 NmM3 / 0.8 Nm
KP
T
Drift
TN
kp
T
Drift
TN
KP
T
Drift
TN
Fig. 5-4 Resolver control with standard interface and analog interface
Note
When using non–PELV circuits at terminals AS1, AS2, connector coding must
be used so that the connectors cannot be interchanged (refer to EN60204–1,
Section 6.4).
Order No. of the coding, refer to Catalog NC 60.
Resolver control
with standard
interface
5 Control Modules