5.10 Control module ANA module
5-160
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) 05.01 Edition
!
Caution
The +24 V outputs of shutoff valves, axes 1 and 2 are shortcircuit proof. The
energy absorbed when switchingoff inductive loads must be limited by the
user to 1.7 J. When incorrectly connected (polarity interchanged), the outputs
are not protected against overload.
The modulespecific enable is realized via terminal 663. The input is evaluated
via the optocoupler in the ANA module. The enable voltage can be taken from
terminal 9.
Terminal 663 is referred to the internal enable voltage (ground, terminal 19).
5.10.3 Bus interfaces
(refer to SIMODRIVE 611A/D)
S X141: Input
S X341: Output
A bus terminating connector must be inserted at the last module.
(refer to SIMODRIVE 611A/D)
S X151: Equipment bus
J
Enable inputs
Drive bus
Equipment bus