5
05.01
5.10 Control module ”ANA module”
5-159
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
26.5 V external supply, enable, BERO inputs
S X431: Axis 1
S X432: Axis 2
Table 5-30 Connector X431; 8–pin Phoenix Combicon connector
Pin X431 Type
1)
Function Typ. voltage/
limit values
1 M I Electronics ground
2 PV1 O P24EXT switched, axis 1 max. 2.0 A
3 MV1 O M24EXT switched, axis 1
4 C1 – Reserved, do not connect
5 P24 I Input +24 V external 26.5 V "2 %
6 M24 I Input 0 V external
7 663 I Module–specific enable 21 V...30 V
8 9 O Internal +24 V enable voltage
1) I = Input, O = Output
Table 5-31 Connector X432; 8–pin Phoenix Combicon connector
Pin X432 Type
1)
Function Typ. voltage/
limit values
1 M I Electronics ground
2 PV2 O P24EXT switched, axis 2 max. 2.0 A
3 MV2 O M24EXT switched, axis 2
4 C2 – Reserved, do not connect
5 B1 I BERO input, axis 1 13 V...30 V
6 19 O Internal enable voltage, ground term. 19
7 B2 I BERO input, axis 2 13 V...30 V
8 9 O Internal enable voltage, +24 V
1) I = Input, O = Output
Notice
It is not permissible to establish a connection (jumper) between X431.6 and
X432.3!
Max. terminal cross–section 2.5 mm
2
.
It is only necessary to supply terminal X431, pins 5 and 6, with 24 V, if the 24 V
outputs of connector X111/112, X121/122 or X431/432 are to be used.
Terminals
5 Control Modules