9
05.01
9.2 Infeed modules
9-232
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
9.2.6 Sequence diagram, central signals at the NE module
P15/N15 fault (red LED lit)
P5 fault (red LED lit)
Supply fault (red LED lit)
VDC link fault (red LED lit)
Pre–charging completed
(yellow LED lit)
S1.2=OFF
Terminal 63=ON
Terminal 64=ON
Speed controller at endstop
(red LED below)
Heatsink overtemperature
(red LED below)
Tachometer fault (red LED top)
Rotor position encoder fault
(red LED top)
S3.6=OFF
Terminal 663=ON
Terminal 65=ON
Feed drive, standard – ready
Speed controller at endstop
(red LED lit)
Heatsink overtemperature
(red LED lit)
Encoder fault (red LED lit)
S5.5=ON
Terminal 663=ON
Terminal 65=ON
Resolver–standard – ready
NC ready
Drive – ready (red LED dark)
FD/MSD digital – ready
Feed drive – user–friendly ?
l*2 monitoring
Heatsink overtemperature/alarm
Standard induction motor ?
Motor overtemperature
Axis module OK
NE ready (term. 72–74)
NO
NO
NO
NO
Yes
Yes
Yes
Yes
NO
NO
NO
NO
Yes
Yes
Yes
NO
NO
NO
Yes
Yes
Yes
Yes
NO
NO
NO
NE
NE ready, internal
FD standard
Resolver–standard
840D
NC ready
FD/MSD digital
Yes
I/R module?
Heatsink overtemperature
l*t/TMP (term. 5.1–5.3)
Yes
NO
NE
NE module OK
NO
Axis module
NO
Yes
Yes
NO
NO
NO
NO
810D
9 Important Circuit Information