6
05.01
6.3 Technical data
6-171
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
6.3 Technical data
Table 6-3 Technical data, I/R modules
Internal cooling
External cooling
Hose cooling
6SN 1145–
6SN 1146–
6SN 1145–
1BA0.–0BA1
1BB0.–0BA1
–
1BA0.–0CA1
1BB0.–0CA1
–
1BA0.–0DA1
1BB0.–0DA1
1BB0.–0DA1
1BB0.–0EA1
1BB0.–0EA1
1BB0.–0EA1
1BB0.–0FA1
1BB0.–0FA1
1BB0.–0FA1
Infeed:
Rated power (S1)
Infeed power (S6–40%)
Infeed peak
power
KW
KW
KW
16
21
35
36
47
70
55
71
91
80
104
131
120
156
175
Regenerative feed-
back:
Continuous regenera-
tive
feedback power
Regenerative feedback
peak power
KW
KW
16
35
36
70
55
91
80
131
120
175
Connection data
Voltage
Frequency
V
Hz
3–ph. 400 V AC –10 % to 3–ph. 480 V AC +6 %
50 to 60 10 %
Rated current
(400V/480V)
Input current at
360 V
AC
Input current for (480V;
S6–40%)
Peak current
(400V/480V)
Connection cross–
section, max.
A
A
A
A
mm
2
27/22.5
30
29.6
59/49.2
16
60.5/50.4
67.3
65.8
117.5/97.9
50
92.5/77.1
103
99.2
153/127.5
95
134/111.7
149
145.8
220/183.3
95
202/168.3
224.5
218.3
294/245
150
Output voltage V 600 / 625 / 680
Output current at
600 V
DC
Rated current
Output current (480V;
S6–40%)
Peak current
A
A
A
22.1
29.2
48.3
50
65
96.7
75.8
98.3
125.8
110.8
144.2
181.7
166.7
216.7
242.5
Module width mm 100 200 300 300 300
Cooling type
Internal cooling
External cooling
Internal
separately–
driven fan
Internal
separately–
driven fan
Internal sepa-
rately–driven
fan
Mounted fan Mounted fan
Hose cooling
Integrated
separately–
Integrated
separately–
Fan assembly and mounted fan required
driven fan
–
driven fan
–
Kit for hosing cooling with fan
Cooling type
Internal cooling
External cooling
Hose cooling
W
W (int./ext.)
W (int./ext.)
320
50/270
–
585
50/535
–
745
115/630
115/630
1280
190/1090
190/1090
1950
290/1660
290/1660
Efficiency η 0.97 0.975 0.977 0.977 0.978
Weights
Internal cooling
External cooling
Hose cooling
kg
kg
kg
10.5
10.5
–
15.5
15.5
–
26
26
26
26
26
26
29
29
29
6 Infeed Modules