6
05.01
6.3 Technical data
6-172
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Table 6-4 Technical data, UI modules
Internal cooling
External cooling
Hose cooling
6SN 1145–
6SN 1146–
6SN 1145–
–
1AA0.–0AA1
–
1AA0.–0CA0
1AB0.–0CA0
–
1AA0.–0CA0
1AB0.–0CA0
–
Infeed:
Rated power (S1)
Infeed power (S6–40%)
Infeed peak
power
KW
KW
KW
5
6.5
10
10
13
25
28
36
50
Continuous/peak power
of the integrated pulsed
resistor
KW 0.2/10 0.3/25 –
Connection data:
Voltage
Frequency
V
Hz
3–ph. 400 V AC –10 % up to 3–ph. 480 V AC +6 %
50 to 60 10 %
Rated current
Input current for
360 V
AC
Peak current
Connection cross–sec-
tion, max.
A
A
A
mm
2
9.4
12.3
18.8
6
18.2
23.8
38.8
16
48.8
62.5
87.1
50
Output voltage V 490 to 680 +6 %
Output current for
650 V
DC
Rated current
Output current
(S6–40%)
Peak current
A
A
A
7.8
10
15.5
15.4
20
38.8
43.3
55.8
77.5
Module width mm 50 100 200
Cooling type
Internal cooling
External cooling
Non–ventilated
Non–ventilated
Universal cooling
internal/external
Internal separately–
driven fan
Hose cooling – – Integrated separately–
driven fan
Cooling type
Internal cooling
External cooling
Hose cooling
W
W (int./ext.)
W (int./ext.)
270
270/–
–
450
119/331
–
745
90/160
–
Efficiency η 0.985 0.985 0.985
Weights
Internal cooling
External cooling
Hose cooling
kg
kg
kg
6.5
6.5
–
9.5
9.5
–
15.5
15.5
–
6 Infeed Modules