4
05.01
4.2 Current de–rating
4-92
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
4.2.4 Information on motor–converter selection MSD control, digital
Various inverter clock frequencies can be parameterized; observe the current
de–rating.
An inverter clock frequency is pre–set for MSD digital f
T
=3.2 kHz: The currents
are a function of the inverter clock frequency f
T
.
Table 4-8 Currents as a function of the inverter clock frequency
LT 50A
LT 80A
LT 108A
LT 120A
LT 160A
LT 200A
LT 300A
LT 400A
20/27/27
26/35/44
39/52/66
39/52/66
51/69/87
74/96/111
103/129/165
171/214/220
LT 50A
LT 80A
LT 108A
LT 120A
LT 160A
LT 200A
LT 300A
LT 400A
Code
No.
Code
No.
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
6
7
13
8
9
10
11
12
24/32/32
30/40/51
45/60/76
45/60/75
60/80/102
85/110/127
120/150/193
200/250/257
23/31/31
30/39/50
44/59/75
44/59/75
59/79/100
84/108/125
118/147/190
196/246/252
23/31/31
29/39/49
43/58/73
43/58/73
58/77/98
82/106/123
116/144/186
193/241/247
23/30/30
28/38/48
43/57/72
43/57/72
57/75/96
81/104/120
113/141/182
188/235/242
22/29/29
28/37/47
42/56/70
42/56/70
55/73/94
79/102/117
110/138/177
183/229/236
21/28/28
27/36/46
40/54/68
40/54/68
53/71/91
76/99/114
107/133/171
178/222/228
19/25/25
25/34/43
38/50/64
38/50/64
49/66/84
71/92/107
98/123/158
164/205/211
18/23/23
24/32/41
36/48/61
36/48/61
47/62/79
68/88/102
93/117/150
156/195/200
16/22/22
23/30/38
34/45/57
34/45/57
44/58/74
64/83/96
87/109/140
145/182/187
14/19/19
21/28/36
32/42/53
32/42/53
40/53/68
60/77/89
80/100/129
133/167/171
12/16/16
19/25/32
29/38/48
29/38/48
36/47/60
54/70/80
71/89/114
119/148/152
10/13/13
17/22/28
25/33/42
25/33/42
30/40/51
47/61/70
60/75/97
100/125/129
6
7
13
8
9
10
11
12
f
T
3.20 kHz
f
T
3.37 kHz
f
T
3.56 kHz
f
T
3.76 kHz
f
T
4.00 kHz
f
T
4.27 kHz
Power
module
type
Power
module
type
f
T
4.57 kHz
f
T
4.92 kHz
f
T
5.33 kHz
f
T
5.82 kHz
f
T
6.40 kHz
f
T
7.11 kHz
f
T
8.00 kHz
4 Power Modules