7
05.01
7.1 Line supply fuses, commutating reactors, transformers and main switches
7-205
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
7.1.3 Assigning commutating reactors to the NE modules
Note
When using SIMODRIVE filter modules for I/R modules in squarewave current
operation (refer to Section 7.2), a separate commutating reactor is not required.
For UI 5/10 kW and UI 10/25 kW, commutating reactors are not required.
Operating voltage: 3–ph. 300 to 520 V AC/45 to 65 Hz
Table 7-2 Assigning commutating reactors to the NE modules
UI
module
28/50 kW
I/R module
16/21 kW
I/R module
36/47 kW
I/R module
55/71 kW
I/R module
80/104 kW
I/R module
120/156 kW
Type 28 kW
commutating
HF reactor
16 kW
commutating
HF reactor
36 kW
commutating
HF reactor
55 kW
commutating
HF reactor
80 kW
commutating
HF reactor
120 kW
commutating
HF reactor
Order No.
6SN1111–
0AA00–
6SN1111–
1AA00–
0CA0
1)
–0BA1
1)
–0CA1
1)
–0DA1
1)
–1EA0
1)
–1FA0
1)
L
phase
0.15 mH 0.7 mH 0.4 mH 0.27 mH 0.23 mH 0.2 mH
I
n
65 A 30 A 67 A 103 A 150 A 225 A
Voltage
drop/
phase
V3.1 8.6 V 12.3 V 12.3 V 11.1 V 15.2 V
Pv 70 W 170 W 250 W 350 W 450 W 590 W
Connec-
tion
max. 35 mm
2
max. 16 mm
2
max. 35 mm
2
max. 70 mm
2
Cable lug acc. to DIN 46235
Weight
(max)
6 kg 9 kg 20 kg 26 kg 40 kg 50 kg
Mounting
position
Any Any Any Any Any Any
Terminal Input:
assign-
ment
1U1, 1V1, 1W1
ment
Output:
1U2, 1V2, 1W2
Drilling
template
Dimen-
sions in
mm
Top view,
foorprint
Height
190
11
5.8
166
200
100
68
15
150 136
8
175
330
Height for 16 kW: 145
Height for 36 kW: 230
Height for 55 kW: 280
8
18
15
10
142
156
380
175
325
1)
1): 80kW: 224, Height 200
120kW: 264, Height 300
170170
1)
Suitable for sinusoidal current and squarewave current operation.