7.1 Line supply fuses, commutating reactors, transformers and main switches
7-206
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
7.1.4 Assigning autotransformers to the I/R modules
2)
Note
If a transformer is used for I/R modules, this does not replace the external
commutating reactor.
When using a transformer, from NE module  10kW onwards
Order number: 6SN114V–1VV0V–0VV1 an overvoltage limiting module must
be used. Order number: 6SN1111–0AB00–0AA0
Table 7-3 Auto–transformers for 480/440V input voltage
I/R module
16/21 kW
I/R module
36/47 kW
I/R module
55/71 kW
I/R module
80/104 kW
I/R module
120/156 kW
PD type 3–ph.
480/
440/400 V AC
1)
21 kVA
auto–transformer
46.5 kVA
auto–transformer
70.3 kVA
auto–transformer
104 kVA
auto–transformer
155 kVA
auto–transformer
Order No.
6SN1111–0AA00–
–0BBV
–0CB0 –0DB0 –0EB0
–0FBV
Pv 170 W 376 W 445 W 550 W 700 W
Connection 16 mm
2
50 mm
2
70 mm
2
Cable lug acc. to DIN 46235
Fuse, primary 35 A gL 80 A gL 125 A gL 160 A gL 224 A gL
Weight 26 kg 60 kg 60 kg 80 kg 125 kg
Terminal
assignment
1U1 / 1U3 / 1V1 / 1V3 / 1W1 / 1W3 / 2U1 / 2V1 / 2W1 / N Flat connectors
1U1 to 1W1=480 V input, 1U3 to 1W3=440 V input, 2U1 to 2W1=400 V output, N=neutral point
Drilling template
Dimensions in mm
Top view, footprint
t3
b4
t4
t1
t2
b3
b2
b1
t1 = 270
t2 = 235
t3 = 35
t4 = 10
b1 = 180
b2 = 140.5
b3 = 39.5
b4 = 18
Height 250
t1 = 370
t2 = 317
t3 = 53
t4 = 10
b1 = 220
b2 = 179
b3 = 41
b4 = 18
Height 330
t1 = 370
t2 = 317
t3 = 53
t4 = 10
b1 = 240
b2 = 189
b3 = 51
b4 = 18
Height 340
t1 = 420
t2 = 368
t3 = 52
t4 = 10
b1 = 260
b2 = 200.5
b3 = 59.5
b4 = 18
Height 370
t1 = 480
t2 = 418
t3 = 62
t4 = 15
b1 = 280
b2 = 217.5
b3 = 62.5
b4 = 22
Height 440
1) The transformers for 3–ph. 480/440/400 V AC can be used at the 480 V tap up to 550 V for a line supply frequency
of 57 – 63 Hz.
2) Assigning isolating transformers to I/R modules, refer to Catalog NC 60.