EasyManuals Logo

Siemens Simodrive 611 Planning Guide

Siemens Simodrive 611
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
4
05.01
4.2 Current derating
4-89
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) 05.01 Edition
4.2.1 Information on the motordrive converter selection, MSD analog
Various inverter clock frequencies can be parameterized; observe the current
derating.
Inverter clock frequency for MSD analog f
0
=3.2 kHz: The currents are a function
of the inverter clock frequency f
T
.
Table 4-5 Currents as a function of the inverter clock frequency
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
In/Is6/Imax
in A
PM
type
Code
No.
f
T
3.20 kHz
f
T
4.70 kHz
f
T
6.30 kHz
f
T
7.80 kHz
f
T
2.80 kHz
f
T
3.90 kHz
f
T
5.00 kHz
f
T
5.90 kHz
LT 50A
LT 80A
LT 108A
LT 120A
LT 160A
LT 200A
LT 300A
LT 400A
6
7
13
8
9
10
11
12
24/32/32
30/40/51
45/60/76
45/60/76
60/80/102
85/110/127
120/150/193
200/250/257
20/26/26
26/34/44
39/52/65
39/52/65
51/68/86
73/95/109
101/127/163
169/211/217
15/20/20
21/28/36
32/43/54
32/43/54
41/54/69
60/78/90
81/102/131
135/169/174
10/14/14
17/23/29
26/34/43
26/34/43
31/42/53
48/63/72
62/78/101
104/130/134
24/32/32
30/40/51
45/60/76
45/60/76
60/80/102
85/110/127
120/150/193
200/250/257
22/29/29
28/37/48
42/56/71
42/56/71
56/74/95
79/103/119
111/139/179
185/232/238
19/25/25
25/33/42
37/50/63
37/50/63
49/65/83
71/91/106
98/122/157
163/203/209
16/21/21
22/30/38
34/45/57
34/45/57
43/58/73
63/82/95
86/108/139
144/180/185
up to including FW 2.xx
from FW 3.0
For special motors with a lower leakage induction, it may be necessary to pro-
vide a series reactor and/or increase the inverter clock frequency of the drive
converter. From experience, motors with low leakage induction are those which
can achieve high stator frequencies (maximum motor stator frequency
> 300 Hz)
or motors with a higher rated current (rated current > 85 A).
I
N
Rated module current at the converter pulse frequency
(standard value: f
0
3.2 kHz)
I
min
Minimum motor current
I
S6
Max. motor current for an S6 load duty cycle
I
Short
Shorttime limiting current of the module used in A
rms
I
0Mot
Noload motor current in A
rms
n
FS
Speed at the start of field weakening
n
max
Max. motor speed
Dimensioning the series reactor, refer to Section 6
4 Power Modules

Table of Contents

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals