9.7 Circuit examples =1 to =10 with SIMODRIVE 611 analog
9-278
Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) 05.01 Edition
Speed monitoring
Settingup operation
When the automatic mode is cancelled, contactor =5K15 deenergized or the
protective door released or opened, contactor =6K11 is deenergized, terminal
6970 opened, and the speed is monitored for standstill. When enabled via
pushbutton =5S11, contactors =5K13/=5K14 are energized and the speed,
set at the monitoring device, for settingup operation, monitored.
When the permissible speed is exceeded, contacts A11/7980 and
A11/7576 open. The pulses for the spindle drive are inhibited, and at the same
time the emergency stop function is initiated via contactor =4K21 and the
drives are shut down.
Automatic operation
When the max. permissible speed, set at the selector switch (the reduction is
programmed as a %) is exceeded, the drives are also immediately shutdown as
described before. The device should be adapted to the speed and pulse fre-
quency of the speed encoder via the speed programming inputs.
Depending on the hazard analysis, it may be necessary to use speed monito-
ring, e.g. also for the feed drives and/or also for the userside machine func-
tions. The control must be appropriately adapted on the user side.
Circuit example =8 Limit switch end position
monitoring
Application/functions
Normally, the end position of the axis traversing range in the machine is monito-
red using software limit switches which become active after the reference point
approach. If, under a fault condition, a software limit switch is passed, and the-
refore a hardware limit switch actuated, contactor =4K21 is deenergized via
the interlocking circuit terminals 8182 in the EMERGENCY STOP circuit. The
drives are braked along the current limit and are then shutdown.
However, an axis can only be effectively braked if there is an appropriate di-
stance between the hardware limit switch and the mechanical end stop of the
axis to take into account brake travel.
The actuated end position limit switches can be disabled via the PLC inputs. In
the settingup mode, the axis can move away from the end position using key
actuated switch S13 and be moved away in the opposite direction using push-
button =5S11, enabling.
9 Important Circuit Information

Table of Contents

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals