SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Technical information
Notice
The listed line filters generate a high leakage current through the protective
conductor. As a result of the high filter leakage current, the line filter and
cabinet must be permanently connected to PE.
The measures in accordance with EN 50178/94, Part 5.3.2.1 must be
implemented, e.g.
1. A copper protective conductor with a minimum cross–section of 10 mm
2
must be connected, or
2. A second conductor should be connected in parallel to the protective
conductor through separate terminals.
This conductor must fulfill the requirements for protective conductors according
to IEC 364–5–543 itself.
!
Warning
Operational electrical equipment has parts and components which are at
hazardous voltage levels.
Incorrect handling of these units, i. e., not observing the warning information
can therefore result in severe bodily injury or material damage.
Only appropriately qualified personnel may commission/start–up this equip-
ment.
This personnel must have in–depth knowledge regarding all of the warning
information and service instructions according to this Guide.
Perfect and safe operation of this equipment assumes professional transport,
storage, mounting and installation as well as careful operator control and ser-
vice.
Hazardous axis motion can occur when working with the equipment.
Further, all of the valid national, regional and plant/system–specific regulations
must be adhered to.
!
Caution
Clear warning information indicating the danger associated with the DC link
discharge voltage must be provided on the modules in the relevant language of
the country where the equipment is used
Note
When handling cables observe the following
S they must not be damaged,
S they must not be stressed and
S they must not come into contact with rotating components.