Operation
7.1 Operation
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
173
BOP20 functions
Table 7- 6 Functions
Name
Description
Backlight The backlight can be set using p0007 in such a way that it switches itself off automatically after
the set time if no actions are carried out.
Switch active drive From the BOP perspective, the active drive is defined using p0008 or using the keys "FN" and
"Arrow up".
Units
The units are not displayed on the BOP.
Access level The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected via the BOP.
Parameter filter The parameter filter in p0004 can be used to filter the available parameters in accordance with
their particular function.
Select status display Actual values and setpoints are displayed on the status display.
The status display can be set via p0006.
User parameter list
Using the user parameter list in p0013, parameters can be selected for access.
Hot swapping The BOP can be unplugged and plugged while energized.
The ON and OFF keys have a function.
When unplugging, the drives are stopped.
After plugging, the drives must be switched on again.
The ON and OFF keys have no function
Unplugging and plugging has no effect on the drives.
Actuate keys The following applies to the "P" and "FN" keys:
When used in a combination with another key, "P" or "FN" must be pressed first and then the
other key.
Overview of important parameters (see the SINAMICS DCP List Manual)
All drive objects
p0005 BOP operating display selection
p0006 BOP operating display mode
p0013 BOP user-defined list
p0971 Drive object, save parameters