Electrical connection
5.5 Terminals on the CUD and connector board
SINAMICS DCP
58 Operating Instructions, 09/2019, A5E34382853K
Table 5- 3 Assignment, terminal -X177
Termi-
nal
-X177
Function
Technical specifications
Analog inputs (assignable inputs)
1
2
AI 3 +
AI 3 -
Analog input 3 Bipolar voltage inputs
- differential input ±10 V
- input resistance 150 kΩ
- resolution, approximately 5.4 mV (±11 bit)
- common mode controllability: ±15 V
3
4
AI 4 +
AI 4 -
Analog input 4
5
6
AI 5 +
AI 5 -
Analog input 5
7
8
AI 6 +
AI 6 -
Analog input 6
Digital inputs (assignable inputs)
9
10
24 V DC 24 V supply (output) 24 VDC, short-circuit proof
Max. load 200 mA (terminals 9 and 10 combined),
internal supply in relation to internal ground
11
DI 0
Digital input 0
H signal: +15 V to +30 V
L signal: – 30 V to +5 V or terminal open circuit
8.5 mA at 24 V
12
DI 1
Digital input 1
13
DI 2
Digital input 2
14
DI 3
Digital input 3
Digital inputs/outputs (assignable inputs/outputs)
15
DI/DO 4
Digital input/output 4
Digital inputs or outputs that can be parameterized
Input characteristics:
H signal: +15 V to +30 V
L signal: 0 V to +5 V or terminal open
8.5 mA at 24 V
Output characteristics:
H signal: +20 V to +26 V
L signal: 0 to +2 V
short-circuit proof; max. current carrying capacity: 100 mA per DO;
max. total load of all DO (-X177:15-22): 800 mA
Internal protection circuit (free-wheeling diode)
If overload occurs: Alarm A60018
16
DI/DO 5
Digital input/output 5
17
DI/DO 6
Digital input/output 6
18 DI/DO 7 Digital input/output 7
19
DO 0
Digital output 0
Digital outputs
H signal: +20 V to +26 V
L signal: 0 to +2 V
short-circuit proof; max. current carrying capacity: 100 mA per DO;
max. total load of all DO (-X177:15-22): 800 mA
Internal protection circuit (free-wheeling diode)
If overload occurs: Alarm A60018
20
DO 1
Digital output 1
21
DO 2
Digital output 2
22
DO 3
Digital output 3
23, 24 M Ground, digital
35, 36
M
Ground, digital