Electrical connection
5.5 Terminals on the CUD and connector board
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
59
Analog inputs, setpoint inputs (assignable inputs)
25
26
AI 0 +
AI 0 -
Analog input 0 Input type (signal type) can be parameterized:
• Bipolar voltage input 0...10 V
- differential input ±10 V
- input resistance: 150 kΩ
• Bipolar current input 0...20 mA
- current input -20 mA...20 mA
- input resistance: 300 Ω
• Unipolar current input 4...20 mA
- current input 4...20 mA
- input resistance: 300 Ω
- wire break monitoring
Resolution: approx. 0.66 mV (±14 bit)
Common mode controllability: ±15 V
27
28
AI 1 +
AI 1 -
Analog input 1
29
30
AI 2 +
AI 2 -
Analog input 2 Bipolar voltage input 0...10 V
- differential input ±10 V
- input resistance: 150 kΩ
- resolution: approx. 0.66 mV (±14 bit)
- common mode controllability: ±15 V
31
P10
Reference voltage ±10 V
(output)
Tolerance ±1% at 25° C Stability 0.1% per 10° K
10 mA short-circuit proof
44 Reserved, do not use
Analog outputs (assignable outputs)
±10 V, max. 2 mA short-circuit proof, resolution ±15 bits