Electrical connection
5.6 Additional system components
SINAMICS DCP
72 Operating Instructions, 09/2019, A5E34382853K
Terminal assignment for option G63
The technical data for terminals X177_1, X177_2 and X177_5 corresponds to the
specifications for terminal X177 on the Connector Board in the version without option G63,
see Table 5-3 Assignment, terminal -X177 (Page 58).
Table 5- 9 Assignment of the terminals on the Terminal Module Cabinet (TMC) (overview)
Terminal
X177_1, X177_2
Function
Description
1st terminal block (X177_1)
1, 2
AI 3 +, AI 3 -
Analog input 3
See X177.1 and 2
3, 4
AI 4 +, AI 4 -
Analog input 4
See X177.3 and 4
5, 6 AI 5 +, AI 5 - Analog input 5 See X177.5 and 6
7, 8
AI 6 +, AI 6 -
Analog input 6
See X177.7 and 8
9, 10 24 V DC 24 V supply (output) 24 VDC, short-circuit proof
Max. load 200 mA (terminals 9, 10, 57, 58, 59 and
60 combined),
internal supply to digital ground and analog ground
11, 12, 13, 14
DI 0, 1, 2, 3
Digital input 0, 1, 2, 3
See X177.11, 12, 13, 14
15, 16, 17, 18 DI/DO 4, 5, 6, 7 Digital input/output 4, 5,
6, 7
See X177.15, 16, 17, 18
19, 20, 21 22
DO 0, 1, 2, 3
Digital output 0, 1, 2, 3
See X177.19, 20, 21, 22, 23, 24
23, 24
M
Ground, digital
25, 26
AI 0 +, AI 0 -
Analog input 0
See X177.25 and 26
27, 28
AI 1 +, AI 1 -
Analog input 1
See X177.27 and 28
29, 30
AI 2 +, AI 2 -
Analog input 2
See X177.29 and 30
31, 32 P10, N10 Reference voltage
±10 V (output)
See X177.31, 32, 33, 34
33, 34
M
Ground, analog
2nd terminal block (X177_2)
35, 36
M
Ground, digital
See X177.35 and 36
37, 38
Reserved, do not use
-
39, 40
Reserved, do not use
-
41, 42
Reserved, do not use
-
43, 44 Reserved, do not use -
45, 46
Reserved, do not use
-
47, 48
Reserved, do not use
-
49, 50 AO 0, M Analog output 0, analog
ground
See X177.49 and 50
51, 52 AO 1, M Analog output 1, analog
ground
See X177.51 and 52
53, 54, 55 Temp 1, 2, 3 Temperature sensor,
motor interface 1
See X177.53, 54, 55
56
M
Ground, analog
See X177.56