Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
AT+CPSI=<time> OK
ERROR
Defined values
<time>
The range is 0-255, unit is second, after set <time> will
report the system information every the
seconds.
System mode, values: “NO SERVICE”, “GSM”, “WCDMA”, “LT E ”, “TDS”…
If module in LIMITED SERVICE state and +CNLSA command is set to 1, the system mode will
display as “GSM-LIMITED”, “WCDMA-LIMITED”…
<Operation Mode>
UE operation mode, values: “Unknown”, “Online”, “Offline”, “Factory Test Mode”, “Reset”, “Low
Power Mode”.
<MCC>
Mobile Country Code (first part of the PLMN code)
<MNC>
Mobile Network Code (second part of the PLMN code)
<LAC>
Location Area Code (hexadecimal digits)
<Cell ID>
Service-cell Identify.
<Track LO Adjust>
Track LO Adjust
<C1>
Coefficient for base station selection
Coefficient for Cell re-selection
<Frequency Band>
Frequency Band of active set
Primary synchronization code of active set.
<Freq>
Downlink frequency of active set.
<SSC>
Secondary synchronization code of active set
Ec/Io value
<RSCP>