EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
42
Defined values
<value>
0 Don’t report
1
Report communication protocol. And report APN, uplink rate, downlink rate if PS call.
Refer to AT&E. The maybe communication
protocol report include
“NONE”,”PPPoverUD”,”AV32K”,”AV64K”,”PACKET”. And APN in string format while
uplink rate and downlink rate in integer format with kb unit.
Examples
AT\V0
OK
3.25 AT&E Set CONNECT Result Code Format About Speed
Description
This para
meter setting determines to report Serial connection rate or Wireless connection speed. It
is valid only ATX above 0.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Write Command Responses
AT&E<value> OK
ERROR
Execution Command Responses
AT&E
Set default value: 1
OK
Defined values
<value>
0 Wireless connection speed in integer format.
1 Serial connection rate in integer format. Such as: “115200”
Examples
AT&E0
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Related product manuals