10.3 AT+CVAUXV Set voltage value of the pin named VREG_AUX1
Description
This command is used to set the voltage value of the pin which is named VREG_AUX1.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CVAUXV=? +CVAUXV: (list of supported <voltage>s)
OK
Read Command Responses
AT+ CVAUXV? +CVAUXV: <voltage>
OK
Write Command
Responses
AT+CVAUXV=<voltage> OK
ERROR
Defined values
<voltage>
Voltage value of the pin which is named VREG_AUX1. The unit is in mV. And the value must the
multiple of 50mv.
Examples
AT+CVAUXV=?
+CVAUXV: (1700-3050)
OK
AT+CVAUXV=2800
OK
AT+CVAUXV?
+CVAUXV: 2800
OK