226
10 Hardware Related Commands
10.1 AT+CVALARM Low and high voltage Alarm
Description
This command is used to open or close the low voltage alarm function.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+CVALARM=? +CVALARM: (list of supported <enable>s), (list of supported <
<low voltage>s), (list of supported high < high voltage>s)
OK
Read Command
Responses
AT+CVALARM? +CVALARM: <enable>,<low voltage>, <high voltage>
OK
Write Command Responses
AT+CVALARM=<enable>[,<l
ow voltage>],[<high voltage>]
OK
ERROR
Defined values
<enable>
0 Close
1 Open. If voltage < < low voltage>, it will report “UNDER-VOLTAGE WARNNING
every 10s. If voltage > <high voltage>, it will report OVER-VOLTAGE
WARNNINGevery 10s.
<low voltage>
Between 3300mV and 4000mV. Default value is 3300.
<high voltage>
Between 4000mV and 4300mV. Default value is 4300.
NOTE
The three parameters will be saved automatically.
Examples
AT+CVALARM=1,3400,4300
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals