EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
61
String type; service provider name on SIM
<display mode>
0 doesn’t display PLMN. Already registered on PLMN.
1 display PLMN
Examples
AT+CSPN=?
OK
AT+CSPN?
+CSPN: “CMCC”,0
OK
4.8 AT+CSQ Query signal quality
Description
This command is used to return received signal strength indication <rssi> and channel bit error rate
<ber> from the ME. Test command returns values supported by the TA as compound values.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command
Responses
AT+CSQ=? +CSQ: (list of supported <rssi>s),(list of supported <ber>s)
OK
Execution Command
Responses
AT+CSQ +CSQ: <rssi>,<ber>
OK
ERROR
Defined values
<rssi>
0 -113 dBm or less
1 -111 dBm
2...30 -109... -53 dBm
31 -51 dBm or greater
99 not known or not detectable
100 -116 dBm or less
101 -115 dBm
102…191 – -114... -26dBm
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Related product manuals