AT+STKFMT? +STKFMT: <value>
Write Command Responses
Defined values
<value>
0 – Disable STK pdu format, decoded command mode.
1 – Enable STK pdu format
NOTE: 7100 default value 0, 7500/7600 default value 1.
Examples
OK
11.6 AT+STENV Original STK PDU Envelope Command
Description
This command is used to original stk pdu envelope command.
NOTE: PDU format supported only.
SIM PIN References
YES Vendor
Syntax
Test Command Responses
ERROR
Defined values
<len>
Integer type, pdu string length
String type, pdu value