EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
62
191 -25 dBm or greater
199 not known or not detectable
100…199 – expand to TDSCDMA, indicate RSCP received
<ber>
(in percent)
0 <0.01%
1 0.01% --- 0.1%
2 0.1% --- 0.5%
3 0.5% --- 1.0%
4 1.0% --- 2.0%
5 2.0% --- 4.0%
6 4.0% --- 8.0%
7 >=8.0%
99 not known or not detectable
Examples
AT+CSQ
+CSQ: 22,0
OK
4.9 AT+AUTOCSQ Set CSQ report
Description
This command is used to enable or disable automatic report CSQ info
rmation, when automatic
report enabled, the module reports CSQ information every five seconds or only after <rssi> or
<ber> is changed, the format of automatic report is “+CSQ: <rssi>,<ber>”.
SIM PIN References
NO Vendor
Syntax
Test Command
Responses
AT+AUTOCSQ=? +AUTOCSQ: (list of supported<auto>s),(list of supported<mod
e>s)
OK
Read Command
Responses
AT+AUTOCSQ? +AUTOCSQ: <auto>,<mode>
OK
Write Command Responses
AT+AUTOCSQ=<auto>[,<
OK
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Related product manuals