EasyManuals Logo

SimCom SIM7500 Series User Manual

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
25
<text>
CONNECT result code string; the string formats please refer ATX/AT\V/AT&E command.
<err>
Service failure result code string; the string formats please refer +CME ERROR result code and
AT+CMEE command.
Examples
ATD>SM3;
OK
VOICE CALL: BEGIN
3.4 ATD><n> Originate call from active memory (1)
Description
This command is used to originate a call to specified number.
SIM PIN References
NO
V.25ter
Syntax
Execution Commands Responses
ATD><n>[;] Originate a voice call successfully:
OK
VOICE CALL: BEGIN
Originate a data call successfully:
CONNECT [<text>]
Originate a call unsuccessfully during command execution:
ERROR
Originate a call unsuccessfully for failed connection recovery:
NO CARRIER
Originate a call unsuccessfully for error related to the MT:
+CME ERROR: <err>
Defined values
<n>
Integer type memory location in the range of locations available in the selected memory, i.e. the
index number returned by AT + CP B R.
<;>
The termination character ";" is mandatory to set up voice calls. It must not be used for data and fax
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals