SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
230
This command is used to read the ADC2 value from modem. ME supports 2 types of ADC, which
are raw type and voltage type.
SIM PIN References
NO Vendor
Syntax
Test Command
Responses
AT+CADC2=? +CADC2: (range of supported <adc>s)
OK
Write Command
Responses
AT+CADC2=<adc> +CADC2: <value>
OK
ERROR
Defined values
<adc>
ADC2 type:
0 – raw type.
2 – voltage type(mv)
<value>
Integer type value of the ADC2.
Examples
AT+CADC2=?
+CADC2: (0,2)
OK
AT+CADC2=0
+CADC2: 187
OK
10.6 AT+CMTE Control the module whether power shutdown when
the module’s temperature upon the critical temperature
Description
This command is used to control the module whether power shutdown when the module’s
temperature upon the critical temperature
SIMCOM CONFIDENTIAL FILE