EasyManuals Logo

SimCom SIM7500 Series User Manual

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
112
+CRLP:<iws>,<mws>,<T1>,<N2>[,<ver2>[,<T4>]]
[...]]
OK
Write Command Responses
AT+CRLP=<iws>
[,<mws>[,<T1>[,<N2>
[,<ver>[,<T4>]]]]]
OK
ERROR
Execution Command Responses
AT+CRLP OK
Defined values
<ver>, <verX>
RLP version number
in integer format, and it can be 0, 1 or 2; when version indication is not
present it shall equal 1.
<iws>
IWF to MS window size.
<mws>
MS to IWF window size.
<T1>
Acknowledgement timer.
<N2>
Retransmission attempts.
<T4>
Re-sequencing period in integer format.
NOTE: <T1> and <T4> are in units of 10 ms.
Examples
AT+CRLP?
+CRLP:61,61,48,6,0
+CRLP:61,61,48,6,1
+CRLP:240,240,52,6,2
OK
6.5 AT+CR Service reporting control
Description
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals