+CRLP:<iws>,<mws>,<T1>,<N2>[,<ver2>[,<T4>]]
[...]]
OK
Write Command Responses
AT+CRLP=<iws>
[,<mws>[,<T1>[,<N2>
[,<ver>[,<T4>]]]]]
OK
ERROR
Execution Command Responses
AT+CRLP OK
Defined values
<ver>, <verX>
RLP version number
in integer format, and it can be 0, 1 or 2; when version indication is not
present it shall equal 1.
<iws>
IWF to MS window size.
<mws>
MS to IWF window size.
<T1>
Acknowledgement timer.
<N2>
Retransmission attempts.
<T4>
Re-sequencing period in integer format.
NOTE: <T1> and <T4> are in units of 10 ms.
Examples
AT+CRLP?
+CRLP:61,61,48,6,0
+CRLP:61,61,48,6,1
+CRLP:240,240,52,6,2
OK