SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
77
5 AT Commands for Network
5.1 AT+CREG Network registration
Description
This command is used to control the presentation of an unsolicited result code +CREG: <stat>
when <n>=1 and there is a change in the ME network registration status, or code +CREG:
<stat>[,<lac>,<ci>] when <n>=2 and there is a change of the network cell.
Read command returns the status of result code presentation and an integer <stat> which shows
whether the network has currently indicated the registration of the ME. Location information
elements <lac> and <ci> are returned only when <n>=2 and ME is registered in the network.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command Responses
AT+CREG=?
+CREG: (list of supported <n>s)
OK
Read Command Responses
AT+CREG?
+CREG: <n>,<stat>[,<lac>,<ci>]
OK
ERROR
+CME ERROR: <err>
Write Command Responses
AT+CREG=<n>
OK
ERROR
+CME ERROR: <err>
Execution Command
Responses
AT+CREG
Set default value
(
<n>=0
)
:
OK
Defined values
<n>
0 – disable network registration unsolicited result code
1 – enable network registration unsolicited result code +CREG: <stat>
2 – enable network registration and location information unsolicited result code +CREG:
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals