Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
<bm>
Broadcast type messages:
0 – type not supported.
1 – type supported.
Examples
+CSMS:1,1,1
+CSMS:0,1,1,1
OK
AT+CSMS=?
+CSMS:(0-1)
OK
7.2 AT+CPMS Preferred message storage
Description
This command is used to select memory storages <mem1>, <mem2> and <mem3> to be used for
reading, writing, etc.
SIM PIN References
YES 3GPP TS 27.005
Syntax
Test Command Responses
+CPMS: (list of supported <mem1>s), (list of supported
<mem2>s), (list of supported <mem3>s)
OK
AT+ CP M S?
+CPMS:<mem1>,<used1>,<total1>,<mem2>,<used2>,<total2>,
<mem3>,<used3>,<total3>
OK
ERROR
+CMS ERROR: <err>
AT+ CP M S= <mem1>
[,<mem2>[,<mem3>]]
+CPMS: <used1>,<total1>,<used2>,<total2>,<used3>,<total3>
OK