EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
148
Write Command
Responses
AT+ CFNSIN=<value> OK
ERROR
Defined values
<value>
Gain value from 0x2000-0x7fff, default value is not a fixed value. It varies with different versions.
Examples
AT+CFNSIN=0x2234
OK
AT+CFNSIN?
+CFNSIN: 0x2000
OK
6.39 AT+CFNSLVL Adjust parameter fnsTargetNS of RX_VOICE_FNS
Description
This command is used to modify the fnsTargetNS of RX_VOICE_FNS in DSP. This command only
be used during call and don’t save the parameter after call.
SIM PIN References
NO Vendor
Syntax
Test Command Responses
AT+ CFNSLV L=? +CFNSLV L : (list of supported <value>s)
OK
Read Command Responses
AT+ CFNSLV L? +CFNSLV L : <value>
OK
Write Command Responses
AT+ CFNSLV L=<value> OK
ERROR
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Related product manuals