143
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
Examples
AT+CECH=0x1234
OK
AT+CECH?
+CECH: 0x0200
OK
6.33 AT+CECDT Inhibit echo during doubletalk
Description
This command is used to adjust additional muting gain applied in DES during doubletalk. It modify
the DENS_gamma_e_dt of TX_VOICE_SMECNS in DSP.
The bigger the value, the stronger the
inhibition .This command only be used during call and don’t save the parameter after call.
SIM PIN References
NO
Vendor
Syntax
Test Command Responses
AT+ CECDT=? +CECDT: (list of supported <value>s)
OK
Read Command Responses
AT+ CECDT? +CECDT: <value>
OK
Write Command
Responses
AT+ CECDT=<value> OK
ERROR
Defined values
<value>
Gain value from 0x0000-0x7fff, default value is not a fixed value. It varies with different versions.
Examples
AT+CECDT=0x1234
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals