EasyManua.ls Logo

SimCom SIM7500 Series

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
176
Test Command
Responses
AT+CMSS=? OK
Write Command
Responses
AT+CMSS=
<index> [,<da>[,<toda>]]
+CMSS: <mr>
OK
ERROR
If sending fails:
+CMS ERROR: <err>
Defined values
<index>
Integer type; value in the range of location numbers supported by the associated memory and start
with zero.
<da>
Destination-Address, Address-Value fi
eld in string format; BCD numbers (or GSM 7 bit default
alphabet characters) are converted to characters of the currently selected TE character set, type of
address given by <toda>.
<mr>
Message Reference
GSM 03.40 TP-Message-Reference in integer format.
<toda>
TP-Destination-Address, Type-of-Address octet in integer format. (when first character of <da> is +
(IRA 43) default is 145, otherwise default is 129). The range of value is from 128 to 255.
NOTE:
In text mode, the maximum length of an SMS depends on the
used coding scheme: It is
160 characters if the 7 bit GSM coding scheme is used.
Examples
AT+CMSS=3
+CMSS: 0
OK
AT+CMSS=3,"13012345678"
+CMSS: 55
OK
7.15 AT+CMGW Write message to memory
Description
This command is used to store message (either SMS-DELIVER or SMS-
SUBMIT) to memory
storage <mem2>.
SIMCOM CONFIDENTIAL FILE