Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
AT+CAOC=?
+CAOC: (list of supported <mode>s)
ERROR
AT+CAOC?
+CAOC: <mode>
OK
ERROR
+CME ERROR: <err>
AT+CAOC=<mode>
+CAOC: <ccm>
OK
OK
ERROR
+CME ERROR: <err>
Execution Command Responses
AT+ CAOC Set default value (<mode>=1):
Defined values
0 – query CCM value
1 – deactivate the unsolicited reporting of CCM value
2 – activate the unsolicited reporting of CCM value
<ccm>
String type, three bytes of the current call meter value in hexadecimal format (e.g. "00001E"
indicates decimal value 30), value is in home units and bytes are similarly coded as ACMmax value
Examples
AT+CAOC=0
+CAOC: "000000"
OK
5.8 AT+CSSN Supplementary service notifications
Description