EasyManuals Logo

SimCom SIM7500 Series User Manual

SimCom SIM7500 Series
413 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #340 background imageLoading...
Page #340 background image
Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
339
The bytes of data to output. The maximum value is 1024 for each AT+CFTPSCACHERD calling.
Examples
AT+CFTPSCACHERD?
+CFTPSCACHERD: 102400
OK
AT+CFTPSCACHERD
+CFTPSGET: DATA, 1024
…
OK
15.4.15 Unsolicited FTPS Codes
Code
Description
+CFTPSNOTIFY: PEER
CLOSED
The FTPS session is closed by the server.
15.4.16 Unsolicited FTPS command <err> Codes
0 FTPS operation succeeded
1 SSL verify alert
2 Unknown FTPS error
3 FTPS busy
4 FTPS server closed connection
5 Timeout
6
FTPS transfer failed
7 FTPS memory error
8 Invalid parameter
9 Operation rejected by FTPS server
10 Network error
15.5 HTTP
15.5.1 AT+CHTTPACT Launch a HTTP operation
Description
This command is used to
launch a HTTP operation like GET or POST. Each <Ctrl+Z> character
presented in the data flow of serial port will be coded as <ETX><Ctrl+Z>. Each <ETX> character
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals