Smart Machine Smart Decision
SIM7500_SIM7600 Series_AT Command Manual_V1.07 2017-12-25
250
Write Command
Responses
AT+CMUX=
<value>[,<subset>[,<port
_speed>[,<N1>[,<T1>[,
<
N2
>[,<
T2
>]]]]]]
OK
ERROR
Defined values
< value >:
0 – currently only 0 is supported (basic operation mode).
< subset >:
Currently omitted
< port_speed >:
Currently omitted, you can set speed before enable multiplexer
< N1>:
1-1500
< T1>:
Currently omitted
< N2>:
Currently omitted
< T2>:
2-1000
Examples
AT+CMUX=?
+CMUX: (0),(0),(1-8),(1-1500),(0),(0),(2-1000)
OK
AT+CMUX?
+CMUX: 0,0,5,1500,0,0,600
OK
AT+CMUX=0
OK
NOTE: Currently only basic operation mode is supported.