<response>
Response to the command passed from SIM card to MT.
Examples
AT+CSIM=?
OK
4.5 AT+CRSM Restricted SIM access
Description
By using AT+CRSM instead of Generic SIM Access AT+CSIM, TE application has easier but
more limited access to the SIM database.
Write command transmits to the MT the SIM <command> and its required parameters. MT handles
internally all SIM-MT interface locking and file selection routines. As response to the command,
MT sends the actual SIM information parameters and response data. MT error result code +CME
ERROR
may be returned when the command cannot be passed to the SIM, but failure in the
execution of the command in the SIM is reported in <sw1> and <sw2> parameters.
SIM PIN References
NO 3GPP TS 27.007
Syntax
Test Command Responses
AT+CRSM=?
OK
Write Command Responses
AT+CRSM=<command>[,<f
ileID>[,<p1>,<p2>, <p3>
[,<data>]]]
+CRSM: <sw1>,<sw2>[,<response>]
OK
ERROR
+CME ERROR: <err>
Defined values
<command>
Command passed on by the MT to the SIM:
176 – READ BINARY
178 – READ RECORD
192 – GET RESPONSE
214 – UPDATE BINARY
220 – UPDATE RECORD
242 – STAT U S
203 – RETRIEVE DATA
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7500 Series and is the answer not in the manual?

SimCom SIM7500 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7500 Series
CategoryControl Unit
LanguageEnglish

Related product manuals